Search scope:
排序: Display mode:
Deformation control criterion of shield tunnel under lateral relaxation of soft soil
Frontiers of Structural and Civil Engineering 2023, Volume 17, Issue 5, Pages 780-795 doi: 10.1007/s11709-023-0944-3
Keywords: shield tunnel lateral relaxation of soil deformation control criterion of segment structure model
Deformation Rate Ratio Criterion (DRRC) and Its Verification in Maoshan Tunnel Excavation
Li Shihui,Song Jun
Strategic Study of CAE 2002, Volume 4, Issue 6, Pages 85-91
Keywords: open complex giant system cave-in accident deformation rate ratio criterion typical information method
Tan Zhongsheng,Hong Kairong,Wan Jianglin,Wang Mengshu
Strategic Study of CAE 2006, Volume 8, Issue 12, Pages 92-96
Keywords: mixed ground tunnel attitude control segment crack segment dislocation
Study on anti crack design method for laminating crack at bottom slab in closure segment
Lin Haifeng,Zhang Dongdong and Zhao Qilin
Strategic Study of CAE 2012, Volume 14, Issue 5, Pages 106-112
Keywords: bridge engineering bottom slab finite element method failure criterion biaxial stress
Frontiers of Structural and Civil Engineering Pages 1033-1046 doi: 10.1007/s11709-023-0973-y
Keywords: shield tunnel bearing capacity failure mechanism segment reinforcement
Optimization of spatial structure designs of control rod using Monte Carlo code RMC
Frontiers in Energy 2021, Volume 15, Issue 4, Pages 974-983 doi: 10.1007/s11708-021-0769-5
Keywords: control rod optimized spatial structure neutronic performance burnup stability
PID neural network control of a membrane structure inflation system
Qiushuang LIU, Xiaoli XU
Frontiers of Mechanical Engineering 2010, Volume 5, Issue 4, Pages 418-422 doi: 10.1007/s11465-010-0117-7
Keywords: PID neural network membrane structure
Manufacturing technique and performance of functionally graded concrete segment in shield tunnel
Baoguo MA, Dinghua ZOU, Li XU
Frontiers of Structural and Civil Engineering 2009, Volume 3, Issue 1, Pages 101-104 doi: 10.1007/s11709-009-0011-8
Keywords: shield tunnel functionally graded concrete segment (FGCS) manufacturing technology performance
Wanghui BU, Zhenyu LIU, Jianrong TAN, Jin CHENG
Frontiers of Mechanical Engineering 2011, Volume 6, Issue 4, Pages 463-467 doi: 10.1007/s11465-011-0225-z
The shield machine is a heavy construction machine for tunnel excavation, and the segment erectorIt is difficult to achieve precise control in the 6-DOF (degree of freedom) erector in the 2-DOF 5-barHence, this paper proposes a redundantly actuated PRPRP radial mechanism for the segment erector.synchronization of the two driving hydraulic cylinders along the radial direction based on the mechanical structure
Keywords: redundant actuation parallel mechanisms five-bar mechanisms segment erectors shield machines
Hu SHI, Guofang GONG, Huayong YANG
Frontiers of Mechanical Engineering 2011, Volume 6, Issue 3, Pages 369-376 doi: 10.1007/s11465-011-0223-1
Focusing on a segment erector of a shield-tunneling machine developed with 6 degrees of freedom (DOF) and controlled by electro-hydraulic proportional systems, the kinematics of the segment erection processthe position and attitude error model, considering a number of factors such as the hydraulic drive, controlFormulas for calculating the position and attitude error of the grip hand of the segment erector areerror analysis, providing a foundation for practical designing, manufacturing, and assembling of the segment
Keywords: shield tunneling machine segment erector kinematics position and attitude precision
Vibration control of a structure using Magneto-Rheological grease damper
Shinya SUGIYAMA, Tomoki SAKURAI, Shin MORISHITA
Frontiers of Mechanical Engineering 2013, Volume 8, Issue 3, Pages 261-267 doi: 10.1007/s11465-013-0268-4
This paper describes an application study of Magneto-Rheological (MR) grease damper to a structureFurthermore, vibration response of a three-story model structure equipped with MR grease damper was investigated
Keywords: vibration control damper smart material Magneto-Rheological (MR) grease MR fluid
Frequency-domain-based Robustness Analysis for PID Generalized Predictive Control
Wang Fanzhen,Chen Zengqiang,Yao Xiangfeng,Yuan Zhuzhi
Strategic Study of CAE 2006, Volume 8, Issue 10, Pages 66-70
The closed-loop feedback structure of PID generalized predictive control (PID - GPC) is proposed,then small-gain criterion is used to obtain a sufficient condition for the robust stability of PID -
Keywords: predictive control robustness frequency domain small-gain criterion PID control
Shaochun WANG, Xi JIANG, Yun BAI
Frontiers of Structural and Civil Engineering 2019, Volume 13, Issue 5, Pages 1200-1213 doi: 10.1007/s11709-019-0546-2
Keywords: shield tunneling structural synthetic fiber concrete hand hole segment joint ultimate bearing capacity
Adaptive selective ES-FEM limit analysis of cracked plane-strain structures
H. NGUYEN-XUAN,T. RABCZUK
Frontiers of Structural and Civil Engineering 2015, Volume 9, Issue 4, Pages 478-490 doi: 10.1007/s11709-015-0317-7
Keywords: cracked structure limit analysis von Mises criterion edge-based strain smoothing second-order cone programming
Experimental research on ductile fracture criterion in metal forming
Song YU, Weiming FENG
Frontiers of Mechanical Engineering 2011, Volume 6, Issue 3, Pages 308-311 doi: 10.1007/s11465-011-0233-z
Ductile fracture criterion is key limitation parameter in material forming.Accuracy predicting surface and internal failure in plastic deformation process affects on the technologyproviding the experimental values of the critical values at fracture, and 11 widely used ductile fracture criterion
Keywords: ductile fracture criteria metal forming process material experiment stress triaxiality
Title Author Date Type Operation
Deformation control criterion of shield tunnel under lateral relaxation of soft soil
Journal Article
Deformation Rate Ratio Criterion (DRRC) and Its Verification in Maoshan Tunnel Excavation
Li Shihui,Song Jun
Journal Article
Shield Driven Tunneling in the Complex Layer:Direction Control of Shield and Preventing Segment Crack
Tan Zhongsheng,Hong Kairong,Wan Jianglin,Wang Mengshu
Journal Article
Study on anti crack design method for laminating crack at bottom slab in closure segment
Lin Haifeng,Zhang Dongdong and Zhao Qilin
Journal Article
Bending failure performance of a shield tunnel segment based on full-scale test and numerical analysis
Journal Article
PID neural network control of a membrane structure inflation system
Qiushuang LIU, Xiaoli XU
Journal Article
Manufacturing technique and performance of functionally graded concrete segment in shield tunnel
Baoguo MA, Dinghua ZOU, Li XU
Journal Article
A redundantly actuated PRPRP radial mechanism in the segment erector of a shield machine for synchronizationcontrol
Wanghui BU, Zhenyu LIU, Jianrong TAN, Jin CHENG
Journal Article
Drive system design and error analysis of the 6 degrees of freedom segment erector of shield tunneling
Hu SHI, Guofang GONG, Huayong YANG
Journal Article
Vibration control of a structure using Magneto-Rheological grease damper
Shinya SUGIYAMA, Tomoki SAKURAI, Shin MORISHITA
Journal Article
Frequency-domain-based Robustness Analysis for PID Generalized Predictive Control
Wang Fanzhen,Chen Zengqiang,Yao Xiangfeng,Yuan Zhuzhi
Journal Article
The influence of hand hole on the ultimate strength and crack pattern of shield tunnel segment joints
Shaochun WANG, Xi JIANG, Yun BAI
Journal Article
Adaptive selective ES-FEM limit analysis of cracked plane-strain structures
H. NGUYEN-XUAN,T. RABCZUK
Journal Article